NEXTFLEX Bisulfite-Seq Barcodes2018-10-19T14:47:43+00:00

METHYLATED ADAPTERS FOR ILLUMINA® RRBS & WGBS LIBRARY PREP

NEXTFLEX® Bisulfite-Seq Barcodes

  • Up to 24 methylated adapters for multiplexing Illumina® RRBS and WGBS libraries are available
  • Considerably reduce your per-sample sequencing cost by barcoded multiplexing
  • Increase your sequencing scale by pooling samples on a single flow cell
  • Compatible with bisulfite-sequencing on the Illumina® sequencing platforms
Download Manual
For research use only. Not for use in diagnostic procedures.

  • NOVA-511911

       $657

    6 BARCODES | 48 RXNS

  • NOVA-511912

       $1,134

    12 BARCODES | 96 RXNS

  • NOVA-511913

       $2,042

    24 BARCODES | 192 RXNS

Pool Multiple Library Preparations in a Single Flow Cell Lane

The NEXTFLEX® Bisulfite-Seq Barcodes are designed to be used with the NEXTFLEX® Bisulfite-Seq Kit. Unlike other NEXTFLEX® Barcodes, the NEXTFLEX® Bisulfite-Seq Barcodes are methylated. The NEXTFLEX® Bisulfite-Seq Barcodes can be used to provide flexibility and high-throughput capabilities in sequencing applications. They significantly increase scale while reducing costs by allowing the user to pool multiple library preparations in a single flow cell lane. The NEXTFLEX® Bisulfite-Seq Barcodes kits accomplish this by using an indexed adapter with a 6 nt unique sequence. This allows for proper differentiation between samples, preventing poor reads from single base errors introduced during PCR.

These methylated adapters can be used with single, paired-end and multiplex reads.

KIT CONTENTS

  • NEXTFLEX® Bisulfite-Seq Adapters (25 µM)
  • NEXTFLEX® Primer Mix (12.5 µM)

SEQUENCES


APPLICATION NOTES


FLYERS


SCIENTIFIC POSTERS

Selected Publications Citing the Use of the NEXTFLEX® Bisulfite-Seq Barcodes:

  • Agarwal, P., et al. (2015) CGGBP1 mitigates cytosine methylation at repetitive DNA sequences. BMC Genomics, 16:390. doi:10.1186/s12864-015-1593-2.
  • Berg, A., et al. (2015) Obesity is Associated With DNA Methylation in Population-Based Adolescents. Circulation. Poster: 131:AP260, Session Title: Obesity.
  • Bewick, A., et. al. (2016) On the origin and evolutionary consequences of gene body DNA methylation. PNAS. 113: 9111 – 9116.
  • Ramesh, V., et. al. (2016) Loss of Uhrf1 in neural stem cells leads to activation of retroviral elements and delayed neurodegeneration. Genes & Development. 30: 2199 – 2212.
  • Satgé, C. et. al. (2016) Reprogramming of DNA methylation is critical for nodule development in Medicago truncatula. Nature Plants 2, 16166. doi:10.1038/nplants.2016.166.
  • Urich, M. A., Nery, J. R., Lister, R., Schmitz, R. J. and Ecker, J. R. (2015) MethylC-seq library preparation for base-resolution whole-genome bisulfite sequencing. Nature Protocols 10, 475–483. doi:10.1038/nprot.2014.114.
  • van der Graafa, A., et al.  (2015) Rate, spectrum, and evolutionary dynamics of spontaneous epimutations. PNAS. 112:21. pg. 6676–6681. doi: 10.1073/pnas.1424254112.
  • Ye, R., et al. (2015) A Dicer-Independent Route for Biogenesis of siRNAs that Direct DNA Methylation in Arabidopsis. Molecular Cell. doi:10.1016/j.molcel.2015.11.015.

Are the NEXTFLEX® Bisulfite-Seq Barcodes methylated?
Yes they are methylated. Methylated barcodes are required for both WGBS and RRBS bisulfite-seq applications.

With which kits can the NEXTFLEX® Bisulfite-Seq Barcodes be used?
The NEXTFLEX® Bisulfite-Seq Barcodes were designed to be used with the NEXTFLEX® Bisulfite-Seq Kit; however, they are compatible with other bisulfite-seq library prep methods and most other DNA-seq applications compatible with Illumina® sequencing platforms. They are not compatible with MeDIP and MeCAP applications, as these protocols require the use of unmethylated barcodes.

At what concentration are the NEXTFLEX® Bisulfite-Seq Barcodes supplied?
They are supplied at a 25 µM concentration.

Are the NEXTFLEX® Bisulfite-Seq Barcodes supplied with PCR primers?
Yes they are. If you need additional PCR primers, they are available in 48, 96, 100, 192, 384 and 768 reaction sizes at a cost of $1/reaction. These are supplied at a concentration of 12.5 µM.

Are the sequences of the indexes used in the NEXTFLEX® Bisulfite-Seq Barcodes available?
Yes. A PDF containing the indexes within the NEXTFLEX® Bisulfite-Seq Barcodes can be downloaded here.

The NEXTFLEX® Bisulfite-Seq Barcodes Kits contain 6, 12 or 24 unique barcodes, enabling the user to multiplex up to 24 samples per flow cell lane. These kits ship on dry ice.

Contact an NGS Expert